Protection & Control
Transformer Protection



T60 Transformer Protection System
  • High-speed, three-phase, multiple winding transformer protection system.
  • Intended for the primary protection and management of small, medium and large power transformers.
  • Large color graphical HMI and high density I/O option available.
845 Transformer Protection System
  • High-speed draw-out multiprocessor-based relay for transformer protection and management.
  • Intended for the primary protection and management of small, medium and large power transformers.
  • Comprehensive transformer health monitoring, diagnostics and reporting with integrated connectivity to single and multi-gas transformer DGA solutions.
345 Transformer Protection System
  • Primary and backup protection of small and medium sized, 2-winding, distribution transformers.
  • Advanced communications and algorithms for magnitude and phase compensation.
  • Temperature monitoring via remote RTD’s using the RMIO module supporting up to 12 RTDs.
  • Draw out or non draw out options as well as draw out with no chassis option available.
P64 Transformer Protection Relay
  • Comprehensive protection for 3 winding transformers, or 2 winding with dual breaker feeding on one side.
  • High and low impedance restricted earth fault (REF), Fast reset (less than 1 cycle) circuit breaker failure element.
  • Integral asset management capability: transformer thermal overload (IEEE Standard C57.91), loss of life (LOL) and through fault monitoring.
  • Integrated full colour display, for single-line diagram control of the protected bay.
P643 - 3 End Transformer Management Relay
  • Comprehensive protection for 3 winding transformers, or 2 winding with dual breaker feeding on one side
  • High and low impedance restricted earth fault (REF), Fast reset (less than 1 cycle) circuit breaker failure element
  • Integral asset management capability: transformer thermal overload (IEEE Standard C57.91), loss of life (LOL) and through fault monitoring
  • IEC 61850/DNP 3.0 redundant Ethernet, supporting self-healing ring, RSTP, dual homing, PRP or HSR
P642 - 2 Winding Transformer Management Relay
  • Comprehensive suite of main and back-up protection for 2 winding applications
  • High and low impedance restricted earth fault (REF), Fast reset (less than 1 cycle) circuit breaker failure element
  • Integral asset management capability: transformer thermal overload (IEEE Standard C57.91), loss of life (LOL) and through fault monitoring
  • IEC 61850/DNP 3.0 redundant Ethernet, supporting self-healing ring, RSTP, dual homing, PRP or HSR
P652 - 2 Winding Transformer Management Relay
  • Protection for 2 winding applications
  • High-speed differential, inrush restraint, REF (high or low impedance modes), thermal overload, backup overcurrent / earth fault protection (HV and LV)
  • Supervision including measurement, monitoring and recording functions
  • Serial communication protocols (Modbus, IEC60870-5-103, DNP3.0)
P645 - 5 End Transformer Management Relay
  • Comprehensive protection for 2 or 3 winding transformers, with dual breaker feeding on up to two sides
  • High and low impedance restricted earth fault (REF), Fast reset (less than 1 cycle) circuit breaker failure element
  • Integral asset management capability: transformer thermal overload (IEEE Standard C57.91), loss of life (LOL) and through fault monitoring
  • Compact 40TE Digital Substation version supporting IEC61850-9-2 LE and IEC61850-8-1 Ed 2
T35 Transformer Protection System
  • Cost effective transformer protection for up to six windings.
  • A Digital three?phase transformer relay designed to protect any size of power transformer with up to six windings/restraints.
  • Large color graphical HMI and high density I/O option available.
P641 Transformer Protection Relay
Retrofit
  • Quick, 3-step solution to upgrade previously installed SR 750 relays to the Multilin 850
  • Eliminates the need for modifications to switchgear cut-outs, re-wiring, and new drawings or re-engineering